MCA 100 BIO BULLETTIN MULTICOMPONENT ANALYZER FOR BIOGAS

 


MCA 100 BIO BULLETTIN MULTICOMPONENT ANALYZER FOR BIOGAS

Features

  • Configurable for gas concentration, analyzer fault, high temperature, etc..
  • MTouch Screen 5.7” Resistive type
  • Calibration : Zero & span user selectable. Automatic calibration ( optional)
  • Electrical supply : from 100 to 240 Vac 47‐63 Hz
  • Pneumatic connection :Rapid fittings 6.0 OD 4.0 ID
  • Mechanical dimensions : 132,5 x 495,0 x 430,5 mm
  • Weight : 15.75 kG

 

Overview

  • Analysis of CO2, CH4, O2, H2S
  • NDIR technology for CO2 and CH4
  • Automatic air purge for long life H2S cell
  • Arm Processor
  • Touch Screen monitor
  • Ethernet and USB Remonting
  • Analog & Digital Signal Output
  • Low cost ownership
  • 19 “ Rack mounting or Wall mounting version
  • Modbus, Profibus, Ethernet ( optional )
  • Autozero
  • Data downloadable on SD Card

The MCA 100 Bio series of gas analyzers by ETG it’s the ideal solution for biogas measurement and industrial combustion applications because of their accuracy, stability, reliability, broad measurement range, and the variety of available form factors. Unlike other analyzers, ETG MCA 100 non‐dispersive infrared (NDIR) gas analyzers measure multiple gases in an instrument with a single optical path platform.

Single‐gas analyzers are inadequate when using methane as a biofuel because the gas often contains large amounts of CO as a contaminant. ETG analyzers have the ability to measure CO2, CO, and O2 in addition to methane and therefore provide the optimal combination of gases for combustion optimization.

The enhanced optics and electronics of our NDIR analyzers have virtually eliminated zero drift after the initial warm up period. The temperature and pressure compensation eliminates the major causes of span drift in many NDIR instruments.

PNEUMATIC/ELECTRIC
MCA 100 BIO BULLETTIN MULTICOMPONENT ANALYZER FOR BIOGAS MCA 100 BIO BULLETTIN MULTICOMPONENT ANALYZER FOR BIOGAS

MECHANICAL DIMENSIONS

MCA 100 BIO BULLETTIN MULTICOMPONENT ANALYZER FOR BIOGAS

Other Version of Biogas Analyzers

MCA 100 BIO BULLETTIN MULTICOMPONENT ANALYZER FOR BIOGAS

  • Wall mounting Biogas analyzer version model 6500
  • Portable Biogas analyzer model 3200 P

SPECIFICATIONS

Response Time : Response times are specified at a sample flow rate of a 1 liter per minute through the MCA 100 sample cell
Data Refresh Rate : 1 second
Warm-up Time : 30 seconds ready, 3 minutes useable, 30 minutes to full performance
Operating Temperature : 0° to 70° C ( 32° to 158° F)
Operating Humidity : To 95% RH ( Non-condensing)
Operating Altitude : -300 to 3.000 m ( -1.000 to 10.000 ft )
Communications (optional) : Ethernet – Profibus – Modbus
Analog Signal Output : 4‐20 ma for each measured compound

MCA 100 BIO BULLETTIN MULTICOMPONENT ANALYZER FOR BIOGAS